portableairconditionersinc.com

Extracooler® Model SCT83AB4 6.5 Ton Spot Cooler
Cools 1600 to 2000 Square Feet
460V 3Phase 20Amp

Product Information

Rentals Available
Daily-Weekly-Monthly

Typically Used For:

Rooms that are 1600 sq.ft. to 2000 sq.ft. in area
460volt, 3 Phase, 60HZ, 20 Amp power is available.
Drop ceiling or other location is available to exhaust heated air.

Other Considerations:

600 BTUs per person over two, if more than two occupants will be occupying the room during cooling.
+ 1,500 BTUs for each window which receives significant daily sunshine
Additional BTU requirements for heat generating equipment such as Computers, Monitors, Servers, UPS’s

** Ceiling duct kit required in most cases.

Accessories

  • Nozzle kit optimizes the ability to direct cool air precisely where needed.
  • Ceiling discharge kit allows condenser-air to be vented to the plenum area above a suspended ceiling.
  • Condenser return-air plenum allows supply-air to be ducted to the condenser coil.
  • Evaporator return-air plenum allows supply-air to be ducted to the evaporator coil.
  • Supply-duct adapter allows user to connect ductwork to unit’s cold-air discharge.
  • Condensate pump kit automatically removes evaporator-coil condensation allowing continuous unit operation.

 

Accessories

PART # ACCESSORY NAME AND DESCRIPTION
DK20SD 20? CEILING DISCHARGE KIT, SCT-83B AND SCT-83AB4
CP-4 20? CONDENSER RETURN-AIR PLENUM, SCT-83B AND SCT-83AB4
DA-14 14? COLD-AIR SUPPLY DUCT ADAPTER, SCT-83B AND SCT-83AB4
EP-4 20? EVAPORATOR RETURN-AIR PLENUM, SCT-83B AND SCT-83AB4
NK-3 (2) 8? NOZZLE KIT, SCT-83B AND SCT-83AB4
P220 CONDENSATE PUMP, 208/230 VOLT, SCT-30B,SCT-42B, SCT-83B AND SCT-83AB4

Specifications

SPECIFICATIONS VALUE
Cooling Capacity
BTU/Hr
77,500
6.5 Ton
Power Supply
Volts/Phase/Hz/Amps
460/3/60/20
Thermostat Control Mechanical
Metering Device TX Valve
Total Power Consumption
(KW)
9.7
Current Consumption
(Amps)
12.2
Recommended Circuit Amps 20
NEMA
Plug Type
Hardwired
Evaporative CFM
Free Discharge
2300
Condensor CFM 3900
Maximum ESP
in WC
0.50
Maximum Duct Length
Feet
40
Condensate Pump Head
(Feet)
15
Operating Limit
(Min/Max F)
65-105
Sound Level
(dB)
71
R-410A Charge
(Oz)
97
L x W x H
(inches)
42 x 30 x 70
Net Weight 650
Shipping Weight 685